• NFC-3050/3006 series intelligent reactive power automatic compensation controller

    NFC-3050/3006 series intelligent reactive power automatic compensation controller

    Nfc-3050 / 3060 high voltage controller

    environment condition

    Altitude: ≤ 2500

    Working temperature: – 20 ℃~ + 60 ℃

    Storage temperature: – 25 ℃ ~ + 70 ℃

    Measurement method: II + 2U 59-690v wide range

    Working power supply: 85V ~ 265V AC / DC power supply

    Protection: over voltage, under voltage, temperature and harmonic

    Control scheme: CO supplement

    Control output mode: static (a) / dynamic (b)

    Number of control capacitor: 12 (model 3050) / 6 (type 3060)

    Human machine interface: LCD

    Communication: RS-485

    Measurement accuracy: ± 0.5%

    Forced circulation: None

    Terminal block: plug in type

    Quadrant control: two quadrants

    Weight: 0.48kg

    anti-interference:

    Pulse column width (MS): 15

    Peak voltage of pulse train: 2KV, 1kV

    Pulse polarity: positive and negative

    Application time (s): 30

    Support background: no

    Opening size: 138 × 138 mm

    Application orientation: industrial customers

  • JKWV 7 Inch Touch screen control low voltage reactive power automatic compensation controller

    JKWV 7 Inch Touch screen control low voltage reactive power automatic compensation controller

    Jkwv-32 series

    environment condition

    Altitude: ≤ 2500

    Working temperature: – 20 ℃~ + 60 ℃

    Storage temperature: – 25 ℃ ~ + 70 ℃

    Measurement method: II + 2U / 3I + 3U / AC sampling

    Working power supply: 220 VAC, 50 Hz

    Protection: over voltage, under voltage, temperature and harmonic

    Control scheme: CO supplement / CO supplement + sub supplement

    Control output mode: network cable control

    Number of control capacitor circuits: 32

    Human machine interface: LCD touch screen

    Communication: RJ45 network interface

    Measurement accuracy: ± 0.5%

    Forced circulation: None

    Terminal block: plug in type

    Quadrant control: two quadrants / four quadrants

    Weight: 2.18kg

    anti-interference:

    Pulse column width (MS): 15

    Peak voltage of pulse train: 2KV, 1kV

    Pulse polarity: positive and negative

    Application time (s): 30

    Whether backstage is supported: Yes

    Opening size: 215 × 152 mm

    Application orientation: industrial customers

  • JKWI-12(A/B)-32-S/D RJ45 network interface intelligent compensation controller

    JKWI-12(A/B)-32-S/D RJ45 network interface intelligent compensation controller

    Jkwi series

    environment condition

    Altitude: ≤ 2500

    Working temperature: – 20 ℃~ + 60 ℃

    Storage temperature: – 25 ℃ ~ + 70 ℃

    Measurement method: II + 2U / 3I + 3U / AC sampling

    Working power supply: 380VAC, 50Hz

    Protection: over voltage, under voltage, temperature and harmonic

    Control scheme: CO supplement / CO supplement + sub supplement

    Control output mode: network interface

    Static (a) / dynamic (b)

    Number of control capacitor: 12 / 32 (A / b)

    Human machine interface: LED

    Communication: RJ45 network interface

    Measurement accuracy: ± 0.5%

    Forced circulation: None

    Terminal block: plug in type

    Quadrant control: two quadrants

    Weight: A: 0.74kg B: 0.78kg

    anti-interference:

    Pulse column width (MS): 15

    Peak voltage of pulse train: 2KV, 1kV

    Pulse polarity: positive and negative

    Application time (s): 30

    Support background: no

    Opening size: 138 × 138mm

    Application orientation: building Park

  • JKWH-21 channel compensation control interface reactive power compensation controller

    JKWH-21 channel compensation control interface reactive power compensation controller

    Jkwh series

    environment condition

    Altitude: ≤ 2500

    Working temperature: – 20 ℃~ + 60 ℃

    Storage temperature: – 25 ℃ ~ + 70 ℃

    Measurement mode: 3I + 3U / AC sampling

    Working power supply: 220 VAC, 50 Hz

    Protection: over voltage, under voltage and harmonic

    Control scheme: CO supplement / sub supplement / CO supplement + sub supplement

    Control output mode: static (a) / dynamic (b)

    Number of control capacitor circuits: 21 (A / b)

    Human machine interface: LCD

    Communication: RS-485

    Measurement accuracy: ± 0.5%

    Forced circulation: None

    Terminal block: plug in type

    Quadrant control: two quadrants

    Weight: A: 1.04kg B: 0.92kg

    anti-interference:

    Pulse column width (MS): 15

    Peak voltage of pulse train: 2KV, 1kV

    Pulse polarity: positive and negative

    Application time (s): 30

    Support background: no

    Opening size: 138 × 138mm

    Application orientation: industrial customers

  • JkwG-32 LCD dot matrix LCD automatic compensation controller

    JkwG-32 LCD dot matrix LCD automatic compensation controller

    Jkwg-32 series

    environment condition

    Altitude: ≤ 2500

    Working temperature: – 20 ℃~ + 60 ℃

    Storage temperature: – 25 ℃ ~ + 70 ℃

    Measurement method: II + 2U / 3I + 3U / AC sampling

    Working power supply: 220 VAC, 50 Hz

    Protection: over voltage, under voltage, temperature and harmonic

    Control scheme: CO supplement / CO supplement + sub supplement

    Control output mode: network cable control

    Number of control capacitor circuits: 32

    Human machine interface: LCD

    Communication: RJ45 network interface / RS-485

    Measurement accuracy: ± 0.5%

    Forced circulation: None

    Terminal block: plug in type

    Quadrant control: two quadrants / four quadrants

    Weight: 0.88kg

    anti-interference:

    Pulse column width (MS): 15

    Peak voltage of pulse train: 2KV, 1kV

    Pulse polarity: positive and negative

    Application time (s): 30

    Whether backstage is supported: Yes

    Opening size: 138 × 138 mm

  • JKWF-12(A/B) series intelligent reactive power automatic compensation controller

    JKWF-12(A/B) series intelligent reactive power automatic compensation controller

    Jkwf series

    environment condition

    Altitude: ≤ 2500

    Working temperature: – 20 ℃~ + 60 ℃

    Storage temperature: – 25 ℃ ~ + 70 ℃

    Measurement mode: 3I + 3U / AC sampling

    Working power supply: 220 VAC, 50 Hz

    Protection: over voltage, under voltage and harmonic

    Control scheme: CO supplement / sub supplement / CO supplement + sub supplement

    Control output mode: static (a) / dynamic (b)

    Number of control capacitor circuits: 12 (A / b)

    Human machine interface: LCD

    Communication: RS-485

    Measurement accuracy: ± 0.5%

    Forced circulation: Yes

    Terminal block: plug in type

    Quadrant control: two quadrants / four quadrants

    Weight: A: 0.86kg B: 0.78kg

    anti-interference:

    Pulse column width (MS): 15

    Peak voltage of pulse train: 2KV, 1kV

    Pulse polarity: positive and negative

    Application time (s): 30

    Support background: no

    Opening size: 113 × 113 mm / 138 × 138mm

    Application orientation: industrial customers

  • JKWE-21(A/B) Connect the composite switch Factory Directly Sales Black Intelligent Reactive Compensation Controller

    JKWE-21(A/B) Connect the composite switch Factory Directly Sales Black Intelligent Reactive Compensation Controller

    Jkwe series

    environment condition

    Altitude: ≤ 2500

    Working temperature: – 20 ℃~ + 70 ℃

    Storage temperature: – 25 ℃ ~ + 70 ℃

    Measurement mode: 1I + 2U / AC sampling

    Working power supply: 220 VAC, 50 Hz

    Protection: over voltage, under voltage and harmonic

    Control scheme: CO supplement

    Control output mode: static (a) / dynamic (b)

    Number of control capacitor circuits: 21 (A / b)

    Human machine interface: LCD

    Communication: RS-485

    Measurement accuracy: ± 0.5%

    Forced circulation: Yes

    Terminal block: plug in type

    Quadrant control: two quadrants

    Weight: 1.14kg

    anti-interference:

    Pulse column width (MS): 15

    Peak voltage of pulse train: 2KV, 1kV

    Pulse polarity: positive and negative

    Application time (s): 30

    Support background: no

    Opening size: 138 × 138mm

    Application orientation: industrial customers

  • JKWD-12(A/B) Connect the composite switch Multiple control mode LCD Intelligent reactive power compensation controller

    JKWD-12(A/B) Connect the composite switch Multiple control mode LCD Intelligent reactive power compensation controller

    Jkwd series

    environment condition

    Altitude: ≤ 2500

    Working temperature: – 20 ℃~ + 60 ℃

    Storage temperature: – 25 ℃ ~ + 70 ℃

    Measurement mode: 1I + 2U / AC sampling

    Working power supply: 220 VAC, 50 Hz

    Protection: over voltage, under voltage and harmonic

    Control scheme: CO supplement

    Control output mode: static (a) / dynamic (b)

    Number of control capacitor circuits: 12 (A / b)

    Human machine interface: LCD

    Communication: RS-485

    Measurement accuracy: ± 0.5%

    Forced circulation: Yes

    Terminal block: plug in type

    Quadrant control: two quadrants / four quadrants

    Weight: A: 0.78kg B: 0.72kg

    anti-interference:

    Pulse column width (MS): 15

    Peak voltage of pulse train: 2KV, 1kV

    Pulse polarity: positive and negative

    Application time (s): 30

    Support background: no

    Opening size: 113 × 113 mm / 138 × 138mm

    Application orientation: industrial customers

  • JKWB1-12(A) LCD screen Connect the composite switch LCD Intelligent reactive power compensation controller

    JKWB1-12(A) LCD screen Connect the composite switch LCD Intelligent reactive power compensation controller

    JKWB1-16

    environment condition

    Altitude: ≤ 2500

    Working temperature: – 20 ℃~ + 60 ℃

    Storage temperature: – 25 ℃ ~ + 70 ℃

    Measurement method: 1i-2u AC sampling

    Working power supply: common for pre measurement

    Protection: over voltage, under voltage, temperature control, harmonic

    Control scheme: CO supplement

    Control output mode: static (a) / dynamic (b)

    Number of control capacitor circuits: 16 (A / b)

    Human machine interface: LCD

    Communication: RJ45 network interface / RS-485

    Measurement accuracy: ± 0.5%

    Forced circulation: None

    Terminal block: screw fixation

    Quadrant control: two quadrants

    Weight: 0.56kg

    anti-interference:

    Pulse column width (MS): 15

    Peak voltage of pulse train: 2KV, 1kV

    Pulse polarity: positive and negative

    Application time (s): 30

    Support background: no

    Opening size: 113 × 113 mm

    Application orientation: public power grid

  • JKWA-12B series intelligent reactive power automatic compensation controller

    JKWA-12B series intelligent reactive power automatic compensation controller

    JKWA-12B

    technical data

    environment condition

    Altitude: ≤ 2500

    Working temperature: – 20 ℃~ + 60 ℃

    Storage temperature: – 25 ℃ ~ + 70 ℃

    Measurement mode: 3I + 3U / AC sampling

    Working power supply: shared with measurement

    Protection: over voltage, under voltage and harmonic

    Control scheme: CO supplement

    Control output mode: dynamic (b)

    Number of control capacitor: 12 (b)

    Human machine interface: LED

    Communication: RS-485

    Measurement accuracy: ± 0.5%

    Forced circulation: None

    Terminal block: screw fixation

    Quadrant control: two quadrants

    Weight: 0.58kg

    anti-interference:

    Pulse column width (MS): 15

    Peak voltage of pulse train: 2KV, 1kV

    Pulse polarity: positive and negative

    Application time (s): 30

    Support background: no

    Opening size: 113 × 113 mm

    Application orientation: public power grid, JP cabinet

    Number of control capacitor: 12 / 32 (A / b)

  • JKWA1-16 Intelligent reactive power compensation of power factor controller 113*113

    JKWA1-16 Intelligent reactive power compensation of power factor controller 113*113

    Environmental conditions of jkwa1-16

    Altitude: ≤ 2500

    Working temperature: – 20 ℃~ + 60 ℃

    Storage temperature: – 25 ℃ ~ + 70 ℃

    Measurement method: ii-2u / 3I + 3U / AC sampling

    Working power supply: 220 VAC, 50 Hz

    Protection: over voltage, under voltage and harmonic

    Control scheme: CO supplement / CO supplement + sub supplement

    Control output mode: network cable control

    Number of control capacitor circuits: 16

    Human machine interface: LCD

    Communication: RJ45 network interface

    Measurement accuracy: ± 0.5%

    Forced circulation: None

    Terminal block: screw fixation

    Quadrant control: two quadrants

    Weight: 0.56kg

    anti-interference:

    Pulse column width (MS): 15

    Peak voltage of pulse train: 2KV, 1kV

    Pulse polarity: positive and negative

    Application time (s): 30

    Support background: no

    Opening size: 113 × 113 mm

    Application orientation: public power grid

  • OEM-JKWD1/JKWF1-16(A/B) series intelligent reactive power automatic compensation controller

    OEM-JKWD1/JKWF1-16(A/B) series intelligent reactive power automatic compensation controller

    OEM series controller

    environment condition

    Altitude: ≤ 2500

    Working temperature: – 20 ℃~ + 60 ℃

    Storage temperature: – 25 ℃ ~ + 70 ℃

    Measurement mode: 1I + 2U / AC sampling

    Working power supply: 220 VAC, 50 Hz

    Protection: over voltage, under voltage, temperature control, harmonic

    Control scheme: CO supplement / sub supplement

    Control output mode: static (a) / dynamic (b)

    Number of control capacitor circuits: 16 (A / b)

    Human machine interface: LED / LCD

    Communication: RS-485

    Measurement accuracy: ± 0.5%

    Forced circulation: Yes

    Terminal block: plug in type

    Quadrant control: two quadrants / four quadrants

    Weight: LCD A: 0.78kg B: 0.72kg

    anti-interference:

    Pulse column width (MS): 15

    Peak voltage of pulse train: 2KV, 1kV

    Pulse polarity: positive and negative

    Application time (s): 30

    Support background: no

    Opening size: 113 × 113 mm