JkwG-32 LCD dot matrix LCD automatic compensation controller

Short Description:

Jkwg-32 series

environment condition

Altitude: ≤ 2500

Working temperature: – 20 ℃~ + 60 ℃

Storage temperature: – 25 ℃ ~ + 70 ℃

Measurement method: II + 2U / 3I + 3U / AC sampling

Working power supply: 220 VAC, 50 Hz

Protection: over voltage, under voltage, temperature and harmonic

Control scheme: CO supplement / CO supplement + sub supplement

Control output mode: network cable control

Number of control capacitor circuits: 32

Human machine interface: LCD

Communication: RJ45 network interface / RS-485

Measurement accuracy: ± 0.5%

Forced circulation: None

Terminal block: plug in type

Quadrant control: two quadrants / four quadrants

Weight: 0.88kg

anti-interference:

Pulse column width (MS): 15

Peak voltage of pulse train: 2KV, 1kV

Pulse polarity: positive and negative

Application time (s): 30

Whether backstage is supported: Yes

Opening size: 138 × 138 mm


Product Detail

Product Tags

Jkwg-32 series reactive power automatic compensation controller man-machine dialogue interface adopts LCD dot matrix LCD, navigation five button design, touch sensitive and fast, support multi language human-machine interface, all electric parameter display, Harmonic data support bar graph + data display at the same time, power factor curve compensation, curve real-time display and record, reactive power compensation adopts RJ45 communication interface, can control 32 channels of intelligent capacitor / module / composite switch / thyristor switch, this machine is equipped with GPRS interface, convenient to access 4G network, login background can be real-time remote, operation and maintenance system operation big data provides complete operation and maintenance of the system Nurses provide protection.

 

Balanced capacitor switching function.

 

Capacitor bank switching controller adopts combination method of code and cycle switching.  protection.multi hardware protection such as self-test function, under/over-voltage protection and under/over-current protection to confirm equipment operate stably

 

Touched LCD Display.

 

Display  main parameters of  power grid, capacitor switching status, working status and fault warning in real time .Pre-set function. Can set paramters such as current transformer ratio,voltage transofromer ratio, over voltage protection,under voltage protection,THDU protection,THDI protection,target power factor,switch  threshold,switch delay,protection delay,groups,capacitor bank No,address for communication terminal,communicaiton rate,teminal password,swtich mode,  working time  etc.


  • Previous:
  • Next:

  • Write your message here and send it to us

    PRODUCT CATEGORIES