Reactive Power Auto Compensation Controller
We have state-of-the-art equipment. Our products are exported for the USA, the UK and so on, enjoying a fantastic status among the clients for Reactive Power Auto Compensation Controller, Cylindrical Power Capacitor , Automatic Power Factor Controller , 40 Kvar Power Capacitor Bank , Our concept is to help presenting the confidence of each buyers with the offering of our most sincere service, and the right product. Our eternal pursuits are the attitude of "regard the market, regard the custom, regard the science" and the theory of "quality the basic, trust the first and management the advanced" for Reactive Power Auto Compensation Controller, We follow up the career and aspiration of our elder generation, and we are eager to open up a new prospect in this field, We insist on "Integrity, Profession, Win-win Cooperation", because we have a strong backup, that are excellent partners with advanced manufacturing lines, abundant technical strength, standard inspection system and good production capacity.
-
NFC-3050/3006 series intelligent reactive power automatic compensation controller
Nfc-3050 / 3060 high voltage controller
environment condition
Altitude: ≤ 2500
Working temperature: – 20 ℃~ + 60 ℃
Storage temperature: – 25 ℃ ~ + 70 ℃
Measurement method: II + 2U 59-690v wide range
Working power supply: 85V ~ 265V AC / DC power supply
Protection: over voltage, under voltage, temperature and harmonic
Control scheme: CO supplement
Control output mode: static (a) / dynamic (b)
Number of control capacitor: 12 (model 3050) / 6 (type 3060)
Human machine interface: LCD
Communication: RS-485
Measurement accuracy: ± 0.5%
Forced circulation: None
Terminal block: plug in type
Quadrant control: two quadrants
Weight: 0.48kg
anti-interference:
Pulse column width (MS): 15
Peak voltage of pulse train: 2KV, 1kV
Pulse polarity: positive and negative
Application time (s): 30
Support background: no
Opening size: 138 × 138 mm
Application orientation: industrial customers
-
JKWV 7 Inch Touch screen control low voltage reactive power automatic compensation controller
Jkwv-32 series
environment condition
Altitude: ≤ 2500
Working temperature: – 20 ℃~ + 60 ℃
Storage temperature: – 25 ℃ ~ + 70 ℃
Measurement method: II + 2U / 3I + 3U / AC sampling
Working power supply: 220 VAC, 50 Hz
Protection: over voltage, under voltage, temperature and harmonic
Control scheme: CO supplement / CO supplement + sub supplement
Control output mode: network cable control
Number of control capacitor circuits: 32
Human machine interface: LCD touch screen
Communication: RJ45 network interface
Measurement accuracy: ± 0.5%
Forced circulation: None
Terminal block: plug in type
Quadrant control: two quadrants / four quadrants
Weight: 2.18kg
anti-interference:
Pulse column width (MS): 15
Peak voltage of pulse train: 2KV, 1kV
Pulse polarity: positive and negative
Application time (s): 30
Whether backstage is supported: Yes
Opening size: 215 × 152 mm
Application orientation: industrial customers
-
JKWI-12(A/B)-32-S/D RJ45 network interface intelligent compensation controller
Jkwi series
environment condition
Altitude: ≤ 2500
Working temperature: – 20 ℃~ + 60 ℃
Storage temperature: – 25 ℃ ~ + 70 ℃
Measurement method: II + 2U / 3I + 3U / AC sampling
Working power supply: 380VAC, 50Hz
Protection: over voltage, under voltage, temperature and harmonic
Control scheme: CO supplement / CO supplement + sub supplement
Control output mode: network interface
Static (a) / dynamic (b)
Number of control capacitor: 12 / 32 (A / b)
Human machine interface: LED
Communication: RJ45 network interface
Measurement accuracy: ± 0.5%
Forced circulation: None
Terminal block: plug in type
Quadrant control: two quadrants
Weight: A: 0.74kg B: 0.78kg
anti-interference:
Pulse column width (MS): 15
Peak voltage of pulse train: 2KV, 1kV
Pulse polarity: positive and negative
Application time (s): 30
Support background: no
Opening size: 138 × 138mm
Application orientation: building Park
-
JKWH-21 channel compensation control interface reactive power compensation controller
Jkwh series
environment condition
Altitude: ≤ 2500
Working temperature: – 20 ℃~ + 60 ℃
Storage temperature: – 25 ℃ ~ + 70 ℃
Measurement mode: 3I + 3U / AC sampling
Working power supply: 220 VAC, 50 Hz
Protection: over voltage, under voltage and harmonic
Control scheme: CO supplement / sub supplement / CO supplement + sub supplement
Control output mode: static (a) / dynamic (b)
Number of control capacitor circuits: 21 (A / b)
Human machine interface: LCD
Communication: RS-485
Measurement accuracy: ± 0.5%
Forced circulation: None
Terminal block: plug in type
Quadrant control: two quadrants
Weight: A: 1.04kg B: 0.92kg
anti-interference:
Pulse column width (MS): 15
Peak voltage of pulse train: 2KV, 1kV
Pulse polarity: positive and negative
Application time (s): 30
Support background: no
Opening size: 138 × 138mm
Application orientation: industrial customers
-
JkwG-32 LCD dot matrix LCD automatic compensation controller
Jkwg-32 series
environment condition
Altitude: ≤ 2500
Working temperature: – 20 ℃~ + 60 ℃
Storage temperature: – 25 ℃ ~ + 70 ℃
Measurement method: II + 2U / 3I + 3U / AC sampling
Working power supply: 220 VAC, 50 Hz
Protection: over voltage, under voltage, temperature and harmonic
Control scheme: CO supplement / CO supplement + sub supplement
Control output mode: network cable control
Number of control capacitor circuits: 32
Human machine interface: LCD
Communication: RJ45 network interface / RS-485
Measurement accuracy: ± 0.5%
Forced circulation: None
Terminal block: plug in type
Quadrant control: two quadrants / four quadrants
Weight: 0.88kg
anti-interference:
Pulse column width (MS): 15
Peak voltage of pulse train: 2KV, 1kV
Pulse polarity: positive and negative
Application time (s): 30
Whether backstage is supported: Yes
Opening size: 138 × 138 mm
-
JKWF-12(A/B) series intelligent reactive power automatic compensation controller
Jkwf series
environment condition
Altitude: ≤ 2500
Working temperature: – 20 ℃~ + 60 ℃
Storage temperature: – 25 ℃ ~ + 70 ℃
Measurement mode: 3I + 3U / AC sampling
Working power supply: 220 VAC, 50 Hz
Protection: over voltage, under voltage and harmonic
Control scheme: CO supplement / sub supplement / CO supplement + sub supplement
Control output mode: static (a) / dynamic (b)
Number of control capacitor circuits: 12 (A / b)
Human machine interface: LCD
Communication: RS-485
Measurement accuracy: ± 0.5%
Forced circulation: Yes
Terminal block: plug in type
Quadrant control: two quadrants / four quadrants
Weight: A: 0.86kg B: 0.78kg
anti-interference:
Pulse column width (MS): 15
Peak voltage of pulse train: 2KV, 1kV
Pulse polarity: positive and negative
Application time (s): 30
Support background: no
Opening size: 113 × 113 mm / 138 × 138mm
Application orientation: industrial customers
-
JKWE-21(A/B) Connect the composite switch Factory Directly Sales Black Intelligent Reactive Compensation Controller
Jkwe series
environment condition
Altitude: ≤ 2500
Working temperature: – 20 ℃~ + 70 ℃
Storage temperature: – 25 ℃ ~ + 70 ℃
Measurement mode: 1I + 2U / AC sampling
Working power supply: 220 VAC, 50 Hz
Protection: over voltage, under voltage and harmonic
Control scheme: CO supplement
Control output mode: static (a) / dynamic (b)
Number of control capacitor circuits: 21 (A / b)
Human machine interface: LCD
Communication: RS-485
Measurement accuracy: ± 0.5%
Forced circulation: Yes
Terminal block: plug in type
Quadrant control: two quadrants
Weight: 1.14kg
anti-interference:
Pulse column width (MS): 15
Peak voltage of pulse train: 2KV, 1kV
Pulse polarity: positive and negative
Application time (s): 30
Support background: no
Opening size: 138 × 138mm
Application orientation: industrial customers
-
JKWD-12(A/B) Connect the composite switch Multiple control mode LCD Intelligent reactive power compensation controller
Jkwd series
environment condition
Altitude: ≤ 2500
Working temperature: – 20 ℃~ + 60 ℃
Storage temperature: – 25 ℃ ~ + 70 ℃
Measurement mode: 1I + 2U / AC sampling
Working power supply: 220 VAC, 50 Hz
Protection: over voltage, under voltage and harmonic
Control scheme: CO supplement
Control output mode: static (a) / dynamic (b)
Number of control capacitor circuits: 12 (A / b)
Human machine interface: LCD
Communication: RS-485
Measurement accuracy: ± 0.5%
Forced circulation: Yes
Terminal block: plug in type
Quadrant control: two quadrants / four quadrants
Weight: A: 0.78kg B: 0.72kg
anti-interference:
Pulse column width (MS): 15
Peak voltage of pulse train: 2KV, 1kV
Pulse polarity: positive and negative
Application time (s): 30
Support background: no
Opening size: 113 × 113 mm / 138 × 138mm
Application orientation: industrial customers
-
JKWB1-12(A) LCD screen Connect the composite switch LCD Intelligent reactive power compensation controller
JKWB1-16
environment condition
Altitude: ≤ 2500
Working temperature: – 20 ℃~ + 60 ℃
Storage temperature: – 25 ℃ ~ + 70 ℃
Measurement method: 1i-2u AC sampling
Working power supply: common for pre measurement
Protection: over voltage, under voltage, temperature control, harmonic
Control scheme: CO supplement
Control output mode: static (a) / dynamic (b)
Number of control capacitor circuits: 16 (A / b)
Human machine interface: LCD
Communication: RJ45 network interface / RS-485
Measurement accuracy: ± 0.5%
Forced circulation: None
Terminal block: screw fixation
Quadrant control: two quadrants
Weight: 0.56kg
anti-interference:
Pulse column width (MS): 15
Peak voltage of pulse train: 2KV, 1kV
Pulse polarity: positive and negative
Application time (s): 30
Support background: no
Opening size: 113 × 113 mm
Application orientation: public power grid
-
JKWA-12B series intelligent reactive power automatic compensation controller
JKWA-12B
technical data
environment condition
Altitude: ≤ 2500
Working temperature: – 20 ℃~ + 60 ℃
Storage temperature: – 25 ℃ ~ + 70 ℃
Measurement mode: 3I + 3U / AC sampling
Working power supply: shared with measurement
Protection: over voltage, under voltage and harmonic
Control scheme: CO supplement
Control output mode: dynamic (b)
Number of control capacitor: 12 (b)
Human machine interface: LED
Communication: RS-485
Measurement accuracy: ± 0.5%
Forced circulation: None
Terminal block: screw fixation
Quadrant control: two quadrants
Weight: 0.58kg
anti-interference:
Pulse column width (MS): 15
Peak voltage of pulse train: 2KV, 1kV
Pulse polarity: positive and negative
Application time (s): 30
Support background: no
Opening size: 113 × 113 mm
Application orientation: public power grid, JP cabinet
Number of control capacitor: 12 / 32 (A / b)
-
JKWA1-16 Intelligent reactive power compensation of power factor controller 113*113
Environmental conditions of jkwa1-16
Altitude: ≤ 2500
Working temperature: – 20 ℃~ + 60 ℃
Storage temperature: – 25 ℃ ~ + 70 ℃
Measurement method: ii-2u / 3I + 3U / AC sampling
Working power supply: 220 VAC, 50 Hz
Protection: over voltage, under voltage and harmonic
Control scheme: CO supplement / CO supplement + sub supplement
Control output mode: network cable control
Number of control capacitor circuits: 16
Human machine interface: LCD
Communication: RJ45 network interface
Measurement accuracy: ± 0.5%
Forced circulation: None
Terminal block: screw fixation
Quadrant control: two quadrants
Weight: 0.56kg
anti-interference:
Pulse column width (MS): 15
Peak voltage of pulse train: 2KV, 1kV
Pulse polarity: positive and negative
Application time (s): 30
Support background: no
Opening size: 113 × 113 mm
Application orientation: public power grid
-
OEM-JKWD1/JKWF1-16(A/B) series intelligent reactive power automatic compensation controller
OEM series controller
environment condition
Altitude: ≤ 2500
Working temperature: – 20 ℃~ + 60 ℃
Storage temperature: – 25 ℃ ~ + 70 ℃
Measurement mode: 1I + 2U / AC sampling
Working power supply: 220 VAC, 50 Hz
Protection: over voltage, under voltage, temperature control, harmonic
Control scheme: CO supplement / sub supplement
Control output mode: static (a) / dynamic (b)
Number of control capacitor circuits: 16 (A / b)
Human machine interface: LED / LCD
Communication: RS-485
Measurement accuracy: ± 0.5%
Forced circulation: Yes
Terminal block: plug in type
Quadrant control: two quadrants / four quadrants
Weight: LCD A: 0.78kg B: 0.72kg
anti-interference:
Pulse column width (MS): 15
Peak voltage of pulse train: 2KV, 1kV
Pulse polarity: positive and negative
Application time (s): 30
Support background: no
Opening size: 113 × 113 mm
Application orientation: industrial customers